Tikkurila uses cookies to ensure the best possible user experience. If you continue on our site, you will approve the use of cookies. Read more.
Tikkurila worldwide
(Previous date 19.11.2015)'

ClimateCooler Uni Topcoat

DESCRIPTION Heat-reflecting water-borne modified acrylate paint.

Painting of roofs. To be used as a system with ClimateCooler Uni Primer.

RECOMMENDED USES Concrete tiles, fiber-cement sheets and primed steel sheet roofs.

  The paint is suitable for roofs Tool: roller Tool: spray Tool: brush
The coverage of the paint on rough surfaces
The coverage of the paint on smooth surfaces
Features Solar reflectance: Reflects up to 80 % of heat radiation depending on color. The best heat-reflectance result will be achieved together with ClimateCooler Uni Primer.

Colour Range Black, light grey, dark brown, tile red, white, and anthracite dark.

3-5 m2/l.

Can sizes 20 l
Application method Brush, roller, or spray (airless). High pressure spray nozzle 0.019" – 0.021" (nominal angle 40°- 50°).
Drying time at 23°C and 50% relative air humidity Withstands rain and dew 1-2 hours after application. Drying will be slower with higher relative humidity of the air and at lower temperatures.  A second coat can be applied earliest 3-4 hours after the first coat.
Wear resistance Good also in industrial and marine climate.
Solids volume approx.30 %.
Density approx. 1.20 kg/l, ISO 2811.
Storage Protect from frost.

Application conditions The surface to be painted must be solid and dry, air temperature at least +8C and relative humidity of the air below 80 %. Schedule the painting work so that the paint film will be dry before the evening dew. Do not paint under the risk of rain.
Preparation Clean the surfaces from dirt, dust, moss and lichen. Use high pressure washer, avoiding damaging the substrate and structures. Apply ClimateCooler Cleaner solution according to instructions if needed.

Applicable national health and safety precautions must be followed in the treatment of substrates containing asbestos.
Priming Use ClimateCooler Uni Primer.
Finishing Mix the paint carefully before use.

Apply one or two coats of ClimateCooler Uni Topcoat, total wet film thickness 200-225 µm.

Note! Check the condition of the roof before starting the work.
The product contains film protecting agents, therefore rainwater flowing from the roof is not recommended to be used for watering plants or washing during the first year from painting.

Cleaning of tools Clean tools with water. Slightly hardened tools can be cleaned with Pensselipesu Tool Cleaner.
Maintenance instructions HHandle the painted surface with care. The surface achieves its final hardness and durability within approx. 4 weeks.
Earliest after 1 month from application the surface can be cleaned with ClimateCooler Cleaner (mixing ratio: 1 part of cleaner in 50 parts of water).
Maintenance treatment Surfaces painted with ClimateCooler Uni Topcoat should be maintenance painted with the same system.
EU VOC 2004/42/EC-limit value (cat A/i) 140g/l(2010)
ClimateCooler Flex Topcoat contains VOC max. 140g/l.

according to Regulation (EC) No. 1272/2008
Harmful to aquatic life with long lasting effects. Contains reaction mass of: 5-chloro-2-methyl-4-isothiazolin-3-one [EC no. 247-500-7] and 2-methyl-2H-isothiazol-3-one [EC no. 220-239-6] (3:1) and 2-octyl-2H-isothiazol-3-one. May produce an allergic reaction. Wear protective gloves. Avoid release to the environment. A Safety Data Sheet is available on request. CLIMATECOOLER_UNI_TOPCOAT_EN

ENVIRONMENTAL and WASTE DISPOSAL Avoid spillage into drains, water systems and soil. Recycle empty, dry cans or dispose them of in accordance with local regulations. Destroy liquid waste according to the local regulations for hazardous waste.
TRANSPORT Not classified.