DESCRIPTION Heat-reflecting solvent-borne one-component moisture-curing polyurethane coating. Creates a thick waterproofing membrane.
PRODUCT FEATURES

Bitumen, fiber-cement sheets and concrete tiles.

Used as a system with ClimateCooler Hypercoat Primer.

RECOMMENDED USES Especially for flat roofs with ponding water, or extremely worn bitumen roofs.

TECHNICAL DATA
  The paint is glossy Tool: roller Tool: spray Tool: brush
The coverage of the paint on rough surfaces
1.5
The coverage of the paint on smooth surfaces
1.8
Features Solar reflectance: Reflects up to 80 % of infrared radiation.
Colour Range White.
Gloss grade Gloss
Coverage Minimum total consumption depending on substrate 1.5-1.8 kg/m2 applied twice.
Can sizes 15kg
Mixing ratio ClimateCooler Hypercoat Thinner.
Application method

Brush, spiked roller, or spray.

Drying time at 23°C and 50% relative air humidity Touch dry after 2-3 hours; recoatable between 6 - 48 hours. The second coat must be applied latest after 48 hours. Fully cured after 4 days.
Weather resistance Good weather resistance.
Heat resistance Good heat, mechanical and chemical resistance.
Solids volume approx.77 %.
Density approx. 1.4 kg/l, ISO 2811.
Storage Once opened, use as soon as possible.

APPLICATION DETAILS
Application conditions The surface to be painted must be clean, solid and dry, air temperature +8–35C and relative humidity of the air should not exceed 85 %.

Preparation Clean the surfaces using a high-pressure washer, if possible. Remove oil, grease and wax contaminations. Cement laitance, loose particles and cured membrane must be removed.

Applicable national health and safety precautions must be followed in the treatment of substrates containing asbestos.
Priming Use always ClimateCooler Hypercoat Primer.
Finishing Mix the paint carefully before use.

Use a low speed (300 rpm) mixer. Apply the paint with a brush or spiked roller. For spray application, add 5 – 10 % ClimateCooler Hypercoat Thinner. Maximum interval between application of coats should not exceed 48 hours.

Apply two coats of ClimateCooler Hypercoat. Use 900 g/m2 for the first coat. Use a glass fiber mesh in order to make the membrane stronger and more resistant to cracks in the substrate. The glass fiber is incorporated in the wet layer with a spiked roller. The second layer, 700 g/m2 should be applied within 48 hours.


NOTE! Check the condition of the roof before starting the work.
Cleaning of tools Rollers will not be reusable. Clean spray guns with ClimateCooler Hypercoat Thinner.
Maintenance instructions Surfaces painted with ClimateCooler Hypercoat should be maintenance painted with the same product.
Handle the painted surface with care. The surface achieves its final hardness and durability within approx. 4 days.
EU VOC 2004/42/EC-limit value (cat A/i) 500 g/l(2010)
ClimateCooler Hypercoat contains VOC max. 500 g/l.

HEALTH AND SAFETY LABELLING
according to Regulation (EC) No. 1272/2008
Contains: Reaction mass of m-xylene and o-xylene and p-xylene and ethylbenzene. Warning. Flammable liquid and vapor. Causes serious eye irritation. Causes skin irritation. May cause damage to organs through prolonged or repeated exposure. Contains toluene diisocyanate. May produce an allergic reaction. Avoid breathing mist/vapors/spray. Wear protective gloves/clothing. In case of inadequate ventilation wear respiratory protection. Keep away from sparks and open flames. - No smoking. IF IN EYES: Rinse cautiously with water for several minutes. Contains isocyanates. May produce an allergic reaction. A Safety Data Sheet is available on request. CLIMATECOOLER_HYPERCOAT_EN

ENVIRONMENTAL and WASTE DISPOSAL Avoid spillage into drains, water systems and soil. Recycle empty, dry cans or dispose them of in accordance with local regulations. Destroy liquid waste according to the local regulations for hazardous waste.
TRANSPORT 3 III.
-