PRODUCT DATA SHEET 05.08.2011 |
|
Temafloor 150 |
|
|
| DESCRIPTION | A two component solvent free epoxy paint. | |
| PRODUCT FEATURES | A solvent free epoxy paint for floors indoors and outdoors. For new and old concrete floors and for surfaces previously treated with concrete paints. Recommended for floors exposed to moderate chemical and mechanical stress in industrial and storage facilities, repair shops etc. | |
| RECOMMENDED USES | Suitable for coating of asphalt floors, floors of garages, staircases, balconies, washing facilities, cellars etc. | |
| TECHNICAL DATA | ||
| Features | Withstands + 70 ºC dry heat and + 60 ºC in immersion. Temafloor Flex hardener makes the paint surface flexible and thus more resistant to moving or cracking of concrete. Fire classification according to standard EN 13501-1 is BFL-s1. | |
| Colour Range | Sunlight will affect on the shade and the gloss of the varnish in the long run. | |
| Colour Cards | TEMASPEED tinting.
|
|
| Gloss groups | Full-gloss | |
| Coverage | Coverage on concrete floors is on the average: Primer 4 - 6 m2/l Topcoat 6 - 8 m2/l Practical coverage depends on the porosity and evenness of the substrate and on the application method. |
|
| Thinner | 1029 | |
| Mixing ratio | Base 3 parts by volume 102-series
Hardener 1 part by volume 930 5148 or Base 2 parts by volume 102-series Flex hardener 1 part by volume 930 5002 |
|
| Application method | Pour the mixture onto the floor, apply with a steel or rubber trowel and level with a roller. | |
| Pot-life (+23°C) | Approx. 20 minutes after mixing, on substrate. | |
| Drying time at 23°C and 50% relative air humidity | Dust dry after 4 hours Recoatable after 8 hours - 2 days Light trucking after 24 hours Fully cured after 7 days
At lower temperature the curing process will last longer. With Temafloor Flex hardener the curing times are a little longer than with standard hardener. |
|
| Solids volume | approx. 100 volume % | |
| Density | 1.7 kg / litre (mixture) | |
| Product code | 102-series | |
| APPLICATION DETAILS | ||
| Application conditions | The relative humidity of the concrete should not exceed 97 %. The temperature of the ambient air, surface or coating should not fall below + 15 ºC during application or drying. Relative humidity of air should not exceed 80 %. | |
| Preparation | New concrete: Remove laitance by power grinding or hydrochloric acid etching. Choose the method best suited for the premises. After grinding remove dust carefully with a vacuum cleaner. Hydrochloric acid etching is carried out with diluted hydrochloric acid (1 part concentrated hydrochloric acid, 4 parts water). Rinse with plenty of water. Dry the floor.
Old concrete: Remove all grease, oil, chemicals and other impurities by MAALIPESU detergent. Remove old peeling paint layer by grinding. Choose the method best suited for the premises. Clean out pot-holes removing all loose friable material. Open cracks with e.g. an abrasive tool. Remove loose material and dust. |
|
| Priming | Prime using 10 - 30 % thinned Temafloor 150 epoxy paint. Pour the mixture immediately onto the floor, apply with a steel or rubber trowel and level with a roller. | |
| Patching | Patch pot-holes and cracks with Colofill putty or a mixture of unthinned Temafloor 150 epoxy paint or Temafloor 200 Primer or 210 epoxy varnish and dry, clean sand. Mixing ratio e.g. 1 part by volume of epoxy paint or varnish mixture and 1 - 2 parts by volume of sand of grain size 0.1 - 0.6 mm. Grind the patched areas before overcoating. | |
| Finishing | Overcoating may be carried out not earlier than 8 hrs after priming. If the primed surface is not overcoated within 48 hrs, it should be abraded. The paint should be thinned 5 - 20 %. Pour the mixture onto the floor, apply with a steel or rubber trowel and level with a roller. | |
| Mixing of components | Mix the correct proportions of base and hardener thoroughly (approx. 2 minutes) by using an industrial hand drill with a paddle. The amount of mixture depends on the area to be coated and on the pot life of the mixture. Insufficient mixing or incorrect mixing ratio will result in uneven drying of the surface, weaken the properties of the coating and risk the success of the application. | |
| Cleaning of tools | Thinner 1029. | |
| EU VOC 2004/42/EC-limit value | VOC 2004/42/EC (cat A/j) 500 g/l (2010)
Temafloor 150: max. VOC < 500 g/l |
|
| HEALTH AND SAFETY CLASSIFICATION | ||
| Containers are provided with safety labels, which should be observed. Further information about hazardous influences and protection are detailed in individual health and safety data sheets. A health and safety data sheet is available on request from Tikkurila Oyj. | ||
| Product safety data sheet | TEMAFLOOR 150 epoxy paint [GB-ENG] | |
| Thinner safety data sheet | THINNER 006 1029 [GB-ENG] | |
| Hardener safety data sheet | TEMAFLOOR 200, 3000 SL, P300 and 150 HARDENER [GB-ENG] | |
| - | ||
The above information, based on laboratory tests and practical experience, has been proved valid at the date marked on the product data sheet. The quality of the product is ensured by our operational system, based on the requirements of ISO 9001 and ISO 14001. As a manufacturer we cannot be responsible for any damages caused by using the product against our instructions or for inappropriate purposes.