PRODUCT DATA SHEET 04.03.2011 |
|||||||||||||||||
Fontecryl SC 50 |
|
|||||||||||||||||
| DESCRIPTION | A waterborne, one component fast drying alkyd modified acrylic paint which contains active anticorrosive pigments. | |||||||||||||||||
| PRODUCT FEATURES |
Suitable for product painting in metal industry and painting stations. Recommended especially as a single coat paint system for steel structures indoors and outdoors. Drying times can be shortened by using higher temperatures. |
|||||||||||||||||
| RECOMMENDED USES | Typical uses are e.g. steel frameworks, machinery and equipment. | |||||||||||||||||
| TECHNICAL DATA | ||||||||||||||||||
| Colour Cards | TEMASPEED FONTE tinting. | |||||||||||||||||
| Gloss groups | Semi-gloss | |||||||||||||||||
| Coverage |
Practical coverage depends on the application method, painting conditions and the shape and roughness of the surface to be coated. |
|||||||||||||||||
| Thinner | Water | |||||||||||||||||
| Application method | By conventional or airless spay. | |||||||||||||||||
| Drying times |
Drying and recoating times are related to the film thickness, temperature, the relative humidity of the air and ventilation. |
|||||||||||||||||
| Solids volume | 40 ± 2 volume % (ISO 3233)
50 ± 2 weight % |
|||||||||||||||||
| Density | 1.2 ± 0.1 kg/l . | |||||||||||||||||
| Product code | 624 -series | |||||||||||||||||
| APPLICATION DETAILS | ||||||||||||||||||
| Application conditions | All surfaces must be dry. The temperature of the ambient air, surface or paint should not fall below +15ºC during application or drying. Relative humidity should be between
20 - 70%. The surface temperature of the steel should remain at least 3ºC above the dew point. |
|||||||||||||||||
| Preparation | Oil, grease, salts and dirt are removed by appropriate means. (ISO 12944-4)
Steel surfaces: Blast clean to grade Sa2½. (ISO 8501-1) If blast cleaning is not possible, phosphating is recommended for cold rolled steel to improve adhesion. Primed surfaces: Oil, grease, salt and dirt are removed from the surface by appropriate means. Repair any damage to the primer coat. Note the overcoating time of primer. (ISO 12944-4) |
|||||||||||||||||
| Priming | Fontecryl 10, Fontecryl AP. | |||||||||||||||||
| Finishing | Fontecryl SC 50. | |||||||||||||||||
| Painting | By conventional or airless spay. The application method the paint can be thinned
0 - 10%. Airless spray nozzle tip 0.011" - 0.015" and nozzle pressure 120 - 160 bar. Spray angle shall be chosen according to the shape of the object. |
|||||||||||||||||
| Cleaning of tools | Water or Fonteclean 1921. The equipment must be cleaned immediately after use before the paint dries. | |||||||||||||||||
| EU VOC 2004/42/EC-limit value | The Volatile Organic Compounds amount is 40 g/litre of paint.
VOC content in paint (thinned 10 % by volume) is 35 g/l. |
|||||||||||||||||
| HEALTH AND SAFETY CLASSIFICATION | ||||||||||||||||||
| Containers are provided with safety labels, which should be observed. Further information about hazardous influences and protection are detailed in individual health and safety data sheets. A health and safety data sheet is available on request from Tikkurila Oyj. For professional use only. | ||||||||||||||||||
| Product safety data sheet | FONTECRYL SC 50 [GB-ENG] | |||||||||||||||||
| - | ||||||||||||||||||
The above information, based on laboratory tests and practical experience, has been proved valid at the date marked on the product data sheet. The quality of the product is ensured by our operational system, based on the requirements of ISO 9001 and ISO 14001. As a manufacturer we cannot be responsible for any damages caused by using the product against our instructions or for inappropriate purposes.