Working instructions
Product data sheet
Paint calculator
Safety Data Sheets

Fontecoat EP 80

A two-component, water-borne, high gloss epoxy topcoat for framework, machinery and equipmen, etc.

The paint is suitable for interior wallsThe paint is water-borneTool: sprayTool: brush
The coverage of the paint on rough surfaces
The coverage of the paint on smooth surfaces

Tough and glossy surface

Water-borne epoxy Fontecoat EP 80 paint forms durable glossy topcoat. The wide range of colors is available.

Good mechanical and chemical resistance

As a water-borne epoxy paint Fontecoat EP 80 has a very good resistance against mechanical and chemical stress and recommended for different steel surfaces with low-VOC demands.

Fontecoat EP 80 is mostly used for


Fontecoat EP 80 - Water-borne epoxy topcoat

Fontecoat EP80
DESCRIPTION A two-component water-borne epoxy topcoat.
PRODUCT FEATURES Used as a topcoat in epoxy paint systems for steel surfaces.
Recommended uses -

Features Resistant against modest mechanical and chemical stress.
Colour Cards Temaspeed Fonte tinting.
Gloss groups Gloss

Recommended film thicknesses

Theoretical coverage




50 µm

105 µm

9.4 m2/l

80 µm

170 µm

5.9 m2/l

Practical coverage depends on the application method, painting conditions and the shape and roughness of the surface to be coated.
Thinner Water
Mixing ratio Base 1 part by volume 169-series
Hardener 1 part by volume 007 1019
Application method By airless spray or brush.
Pot-life (+23°C) 1½ h.
Drying times

DFT 70 µm

+ 15 ºC

+ 23 ºC

+ 35 ºC

Dust dry, after

4 h

2 h

1 h

Touch dry, after

8 h

5 h

2 h

Recoatable by itself, after

16 h

6 h

4 h

Fully cured, after

14 d

7 d

3 d

Drying and recoating times are related to the film thickness, temperature, the relative humidity of the air and ventilation.
Solids volume 47 ± 2 volume % (ISO 3233)
61 ± 2 weight %
Density 1,4 kg/l käyttövalmis seos.
Product code 169-series

Application conditions All surfaces must be dry. The temperature of the ambient air, surface or paint should not fall below +15 ºC during application and drying. Relative humidity should not exceed 70 %. The surface temperature of the steel should remain at least 3 ºC above the dew point.
Preparation Primed surfaces: Oil, grease, salt and dirt are removed from the surface by appropriate means. Repair any damage to the primer coat. Note the overcoating time of primer. (ISO 12944-4)
Priming Fontecoat EP 50 Beige and Temacoat GPL-S Primer.
Finishing Fontecoat EP 80.
Painting By airless spray or brush. If necessary, the paint can be thinned 0 - 10 %. Airless spray nozzle tip 0.011" - 0.015" and nozzle pressure 140 - 180 bar. Spray angle shall be chosen according to the shape of the object.
Mixing of components First stir base and hardener separately. The correct proportions of base and hardener must be mixed thoroughly before use. Use mechanical mixer for mixing.
Cleaning of tools Clean the spraying equipment immediately after use as follows:
1. Run the equipment with water to remove excess paint from the equipment.
2. Run the equipment with a mixture of approx 20% Thinner 1109 in clean water, at least two times.
3. Finally wash with undiluted Thinner 1109.

Wash the equipment with water before starting to paint again. Unwashed equipment can cause serious surface defects.

Contact Tikkurila Technical Service for detailed instructions for cleaning 2-component application equipment.
EU VOC 2004/42/EC-limit value The Volatile Organic Compounds amount is 70 g/litre of paint.
VOC content of paint mixture (thinned by 10% by volume) 65 g/l.

according to Regulation (EC) No. 1272/2008
Containers are provided with safety labels, which should be observed. Further information about hazardous influences and protection are detailed in individual health and safety data sheets. A health and safety data sheet is available on request from Tikkurila Oyj. For industrial and professional use only.
Safety data sheetFontecoat EP 80
Hardener safety data sheetHARDENER 007 1019 [GB-ENG]