Introduction
Systems
Working instructions
Product data sheet
Colors
Paint calculator
Safety Data Sheets
 

Fontecryl SC 50


A water-borne, one-component fast-drying alkyd modified acrylic paint which contains active anti-corrosive pigments. It is mainly developed for painting of machinery and equipment.


The paint is water-borneTool: spray
The coverage of the paint on rough surfaces
5.0
m2/l
The coverage of the paint on smooth surfaces
10.0
m2/l

Tough semi-gloss surface

Fontecryl SC 50 forms a very tough surface with good anti-corrosive properties. The wide range of colors is a big advantage for machinery and equipment producers.

High film-building properties

Especially used as a single-coat paint system for different steel structures. Can be applied up to 200µm wet film thickness.


Fontecryl SC 50 is mostly used for




Paint and coating systems for metal industries


PRODUCT DATA SHEET
15.03.2013

Fontecryl SC 50 - Water-borne acrylic paint

 
Fontecryl SC50
DESCRIPTION A water-borne, one-component fast-drying alkyd modified acrylic paint which contains active anti-corrosive pigments.
PRODUCT FEATURES

Suitable for product painting in metal industry and painting stations. Recommended especially as a single coat paint system for steel structures indoors and outdoors. Drying times can be shortened by using higher temperatures.

Recommended uses Typical uses are e.g. steel frameworks, machinery and equipment.

TECHNICAL DATA
Colour Cards TEMASPEED FONTE tinting.
Gloss groups Semi-gloss
Coverage

Recommended film thicknesses

Theoretical coverage

dry

wet

 

40 µm

100 µm

10.0 m2/l

80 µm

200 µm

5.0 m2/l


Practical coverage depends on the application method, painting conditions and the shape and roughness of the surface to be coated.
Thinner Water
Application method By conventional or airless spay.
Drying times

DFT 80 µm

+ 15 ºC

+ 23 ºC

+ 60 ºC

Dust dry, after

1½ h

30 min

5 min

Touch dry, after

3h

1 ½ h

15 min

Recoatable with the product itself

No limitations


Drying and recoating times are related to the film thickness, temperature, the relative humidity of the air and ventilation.
Solids volume 40 ± 2 volume % (ISO 3233)
50 ± 2 weight %
Density 1.2 ± 0.1 kg/l .
Product code 624 -series

APPLICATION DETAILS
Application conditions All surfaces must be dry. The temperature of the ambient air, surface or paint should not fall below +15ºC during application or drying. Relative humidity should be between
20 - 70%. The surface temperature of the steel should remain at least 3ºC above the dew point.
Preparation Oil, grease, salts and dirt are removed by appropriate means. (ISO 12944-4)

Steel surfaces: Blast clean to grade Sa2½. (ISO 8501-1) If blast cleaning is not possible, phosphating is recommended for cold rolled steel to improve adhesion.

Primed surfaces: Oil, grease, salt and dirt are removed from the surface by appropriate means. Repair any damage to the primer coat. Note the overcoating time of primer. (ISO 12944-4)
Priming Fontecryl 10, Fontecryl AP.
Finishing Fontecryl SC 50.
Painting By conventional or airless spay. The application method the paint can be thinned
0 - 10%. Airless spray nozzle tip 0.011" - 0.015" and nozzle pressure 120 - 160 bar. Spray angle shall be chosen according to the shape of the object.
Cleaning of tools Water or Fonteclean 1921. The equipment must be cleaned immediately after use before the paint dries.
EU VOC 2004/42/EC-limit value The Volatile Organic Compounds amount is 40 g/litre of paint.
VOC content in paint (thinned 10 % by volume) is 35 g/l.

HEALTH AND SAFETY LABELLING
according to Regulation (EC) No. 1272/2008
Containers are provided with safety labels, which should be observed. Further information about hazardous influences and protection are detailed in individual health and safety data sheets. A health and safety data sheet is available on request from Tikkurila Oyj. For professional use only.
Safety data sheetFontecryl SC 50
 
-


Back

Counter for metal coatings

Tikkurila offers wide range of paints and coatings for metal surfaces for different conditions, applications and needs. Tikkurila cost comparison program calculates costs and helps to find the best solution for your project.

VOC counter for metal coatings

Tikkurila VOC calculation program is based on VOC Directive 1999/13/EC valid in the whole EC area, which is aimed to reduce VOC emissions in different industrial activities. The calculation program is meant to be used as a preliminary mapping of solvent emissions.