PRODUCT DATA SHEET
23.04.2014

Temafloor 4000 ESD - Electrically conductive grinding screed

 
Tikkurila Industry 9L
DESCRIPTION Solvent-free Temafloor 4000 ESD grinding screed is prepared by adding conductive sand mixture to Temafloor 401 epoxy varnish mixture.
PRODUCT FEATURES

Forms electrically electrostatic dissipative coating when used with Temafloor 310 ESD primer. Meets the requirements for electrostatic dissipative floor coatings according to EN 61340-5-1. Good impact and good chemical resistance.

Recommended uses Prevents electrostatic discharge damages and recommended in places where electric discharge is not desirable e.g. in electronic industry, production and storing of explosive materials, place with higher risks of ignition.

TECHNICAL DATA
Features Withstands heavy wear. Resistance to chemicals is given case by case. Withstands +110ºC dry heat and +60ºC in immersion.
Colour Range The colour of the screed is determined by the sand used.
Gloss groups Full-gloss
Coverage

For a flat substrate:

 

3mm layer: 3 litres ready for use screed / m2

4mm layer: 4 litres ready for use screed / m2

 

Practical coverage depends on the evenness of the substrate.
Mixing ratio Temafloor 401 mixture
Base 2 parts by volume 008 4002
Hardener 1 part by volume 008 4012

Screed film thickness 3-4mm
1 part by volume Temafloor 401 mixture
4 parts by volume (6 parts by weight) of conductive sand mixture:
• 30% conductive sand
• 70% coloured sand
Application method By adjustable trowel, serrated trowel, float, levelling trowel and screed box.
Pot-life (+23°C) 20-30 minutes on substrate, 10-15 minutes in the mixing container.
Drying time at 23°C and 50% relative air humidity

Dust dry after 6 hours

Light trucking after 24 hours

Recoatable 16-24 hours

Fully cured after 7 days

 

At lower temperature the curing process will last longer.
Solids volume approx. 100%.
Density 1.8-2.0kg / l (mixture), depending on the grain size and the amount of sand. Recommended grain size 0.5-1.2mm.
Product code 008 4002

APPLICATION DETAILS
Application conditions The relative humidity of the concrete should not exceed 97%. The temperature of the ambient air, surface or coating should not fall below +15ºC during either application or drying. Relative humidity of air should not exceed 80%.
Preparation New concrete
Remove laitance by power grinding, vacuum grit blasting or hydrochloric acid etching. Choose the method best suited for the premises. After grinding remove dust carefully with a vacuum cleaner. Hydrochloric acid etching is carried out with diluted hydrochloric acid (1 part concentrated hydrochloric acid, 4 parts water). Rinse with plenty of water. Dry the floor.

Old concrete
Remove all grease, oil, chemicals and other impurities by MAALIPESU detergent. Remove old peeling paint layer by grinding, milling or vacuum grit blasting. Choose the method best suited for the premises. Clean out pot-holes removing all loose friable material. Open cracks with e.g. an abrasive tool. Remove loose material and dust.
Priming Prime using Temafloor 310 ESD primer thinned 20-30% with Thinner 1029 according to the product data sheet. Scatter conductive sand on the fresh primer coat to ensure the screed adhesion and prevent gliding of the screed.
Diluting Do not thin Temafloor 4000 ESD grinding screed.
Screeding Pour the screed mixture onto the floor. If a thin layer is required, apply by an adjustable trowel to the desired screed thickness. Thick layers are applied by a screed box or by a straight-edge and suitable laths to gauge the required thickness. Knead the screeded surface by hands or use a suitable lightweight floating machine.
Overcoating Overcoating can be carried out after 16-24 hours using Temafloor 401 epoxy varnish thinned 20-30% with Thinner 1029. Pour the varnish mixture onto the floor, spread with a rubber trowel and level with a roller.

EN 61340-5-1: When the system is applied according to this product datasheet, the Temafloor 4000 ESD system fulfils the requirements of standard EN 61340-5-1, having a resistance to ground Rg <109 Ω (<108 Ω for newly installed floor) and Rg>50 kΩ. Measured resistance values may vary but are typically 1 MΩ < Rg < 50 MΩ.
Mixing of components Mix the correct proportions of base and hardener thoroughly (approx. 2 minutes) by using a hand drill with a paddle, concrete mixer or power mixer. Add conductive sand mixture to the varnish mixture by mixing carefully at the same time. Insufficient mixing or incorrect mixing ratio will result in uneven drying of the surface, weaken the properties of the screed and risk the success of the application.
Cleaning of tools Thinner 1029.
EU VOC 2004/42/EC-limit value VOC 2004/42/EC (cat A/j) 500 g/l (2010)
Temafloor 4000 ESD: max. VOC < 500 g/l

HEALTH AND SAFETY LABELLING
according to Regulation (EC) No. 1272/2008
Containers are provided with safety labels, which should be observed. Further information about hazardous influences and protection are detailed in individual health and safety data sheets. A health and safety data sheet is available on request from Tikkurila Oyj.
Safety data sheetTemafloor 4000 ESD
Thinner safety data sheetTemafloor 4000 ESD
Hardener safety data sheetTemafloor 4000 ESD

DECLARATION OF PERFORMANCE Declaration of Performance EN13813 Declaration of Performance EN1504-2
 
-


CE
The European harmonized productstandard EN 13813 defines the requirements for Screed materials and floor screeds, including synthetic resin screeds.

This product is tested and CE-labelled in accordance with the tables ZA.1.5 and ZA.3.3 in the appendix ZA.3.
CE logo
Tikkurila Oyj
Kuninkaalantie 1
FI-01301 VANTAA
11
TIK-8400-5013b
EN 13813
Coating/Screed
Abrasion resistance
RWA 10
Chemical resistance
CR 1, 2, 4, 4a, 6, 6b, 7, 7a, 11, 12, 14 (Class 2)
Release of corrosive substances
SR
Water absorption
NPD
Impact resistance
IR4
Sound insulation
NPD
Sound absorption
NPD
Thermal resistance
NPD
Reaction to fire
Cfl
Adhesion strength by pull off test
Adhesion by pull off test:B 2.0


CE
The European harmonized productstandard EN 1504-2 defines the requirements for surface protection systems for concrete.

This product is tested and CE-labelled in accordance with the tables 1d, 1f and 1g in the appendix ZA.
CE logo
0809
Tikkurila Oyj
Kuninkaalantie 1
FI-01301 VANTAA
13
TIK-8400-5013a
EN 1504-2
Coating
Abrasion resistance
< 3000 mg
Resistance to severe chemical attack
Class II
Permeability to CO2
CO2sD > 50 m
Impact resistance
Class I: ≥ 4 Nm
Permeability to water vapour
Class I, sD < 50 m
Capillary absorption and permeability to water
w < 0,1 kg/m² ∙ h0,5
Adhesion strength by pull off test
Adhesion strength by pull off test: ≥ 2,0 N/mm²
Reaction to fire
Cfl-s1
The above information is not intended to be exhaustive or complete. The information is based on laboratory tests and practical experience, and it is given to the best of our knowledge. The quality of the product is ensured by our operational system, based on the requirements of ISO 9001 and ISO 14001. As manufacturer we cannot control the conditions under which the product is being used or the many factors that have an effect on the use and application of the product. We disclaim liability for any damages caused by using the product against our instructions or for inappropriate purposes. We reserve the right to change the given information unilaterally without notice. The product is intended for professional use only and shall only be used by professionals who have sufficient knowledge and expertise on the proper use of the product. The information above is advisory only. To the extent permitted by applicable law, we shall not approve of any liability for the conditions under which the product is being used or for the use or application of the product. In case you intend to use the product for any other purpose than that recommended in this document without first getting our written confirmation on the suitability for the intended use, such use takes place at your own risk.


Back