Introduction
Systems
Working instructions
Product data sheet
Colors
Paint calculator
Safety Data Sheets
 

Temacoat GPL

A two-component, amine-adduct cured epoxy finish. The paint is developed for different types of steelwork and equipment in process industries, etc.

The paint is solvent-borneTool: sprayTool: brush
The coverage of the paint on rough surfaces
5,5
m2/l
The coverage of the paint on smooth surfaces
11
m2/l

Withstands stresses and heat

Temacoat GPL is used particularly as a finishing coat in epoxy systems for objects exposed to heavy abrasion and chemical attack. The paint withstands immersion in water, oil and dilute solutions of non-oxidizing acids, alkalis and salts. Resists +150°C dry heat.

CE-marked product

Temacoat GPL is suitable for concrete surfaces as e.g. bridge piers, etc. and has CE marking. The paint withstands well chemically active gases and dust, and therefore is used a lot in the wood processing and chemical industries.


Temacoat GPL is mostly used for




Paint and coating systems for metal industries


PRODUCT DATA SHEET
26.02.2014

Temacoat GPL - Epoxy finish

 
Temacoat GPL
DESCRIPTION A two-component, amine-adduct cured epoxy finish.
PRODUCT FEATURES

Used especially as a finishing coat in epoxy systems exposed to heavy abrasion and/or chemical stress. Due to CE marking also suitable for concrete surfaces.

Recommended uses Recommended for bridges, tanks and different types of steelwork and equipment in the wood processing and chemical industries, such as tubular bridges, conveyors, paper machines etc.

TECHNICAL DATA
Features Withstands +150 ºC dry heat and +60 ºC in immersion. Withstands immersion in dilute solutions of non-oxidizing acids, alkalis and salts. Resists only temporary splashes of oxidizing acids and bleaching solutions. Withstands chemically active gases and dust. Withstands immersion in mineral/vegetable/animal fats and oils.
Colour Cards RAL, NCS, SSG, BS, MONICOLOR NOVA and SYMPHONY colour cards. TEMASPEED tinting.
Gloss groups Gloss
Coverage

Recommended film thicknesses

Theoretical coverage

dry

wet

 

50 µm

90 µm

11.0 m2/l

100 µm

185 µm

5.5 m2/l


Practical coverage depends on the application method, painting conditions and the shape and roughness of the surface to be coated.
Thinner 1031
Mixing ratio Base 3 parts by volume 170-series.
Hardener 1 part by volume 008 7580
Application method By airless spray or brush.
Pot-life (+23°C) 5 hours
Drying times

DFT 60 µm

+ 10 ºC

+ 23 ºC

+ 35 ºC

Dust dry,after

3 h

2 h

1 h

Touch dry, after

10 h

5 h

2 h

Recoatable,after

10 h

4 h

2 h

Recoatable in immersion, after

32 h

16 h

8 h


Drying and recoating times are related to the film thickness, temperature, the relative humidity of the air and ventilation.
Solids volume 55 ± 2 volume % (ISO 3233)
68 ± 2 weight %
Density 1.3 - 1.4 kg / l (mixed) depending on colour.
Product code 170-series.

APPLICATION DETAILS
Application conditions All surfaces must be dry. The temperature of the ambient air, surface or paint should not fall below +10 ºC during application or drying. Relative humidity should not exceed 80 %. The surface temperature of the steel should remain at least 3 ºC above the dew point.
Preparation Primed surfaces: Oil, grease, salt and dirt are removed from the surface by appropriate means. Repair any damage to the primer coat. Note the overcoating time of primer. (ISO 12944-4)

Concrete surfaces: The surface must be dry and at least 4 weeks old. The relative humidity of the concrete should not exceed 97%. Remove any splashes and unevennesses by grinding. Remove laitance and form oil from concrete castings by sanding or blast cleaning. Any cracks, crevices and voids must be repaired with a mixture of Temafloor 200 and fine dry quartz sand.
Priming Temacoat GPL-S Primer, Temacoat GPL-S MIO, Temacoat SPA and Temabond.
Finishing Temacoat GPL.
Painting By airless spray or brush. If necessary can be thinned 0–10 % for spray application. Airless spray nozzle tip 0.011"–0.017" and nozzle pressure 120–160 bar. Spray angle shall be chosen according to the shape of the object.
At brush application the paint can be thinned according to the circumstances.
Mixing of components First stir base and hardener separately. The correct proportions of base and hardener must be mixed thoroughly before use. Use mechanical mixer for mixing.
Cleaning of tools Thinner 006 1031.
EU VOC 2004/42/EC-limit value The Volatile Organic Compounds amount is 455 g/litre of paint mixture.
VOC content of the paint mixture (thinned 10 % by volume) is 495 g/l.

HEALTH AND SAFETY LABELLING
according to Regulation (EC) No. 1272/2008
Containers are provided with safety labels, which should be observed. Further information about hazardous influences and protection are detailed in individual health and safety data sheets. A health and safety data sheet is available on request from Tikkurila Oyj.
Safety data sheetTemacoat GPL
Thinner safety data sheetTemacoat GPL
Hardener safety data sheetTemacoat GPL
 
-


Back

Counter for metal coatings

Tikkurila offers wide range of paints and coatings for metal surfaces for different conditions, applications and needs. Tikkurila cost comparison program calculates costs and helps to find the best solution for your project.

VOC counter for metal coatings

Tikkurila VOC calculation program is based on VOC Directive 1999/13/EC valid in the whole EC area, which is aimed to reduce VOC emissions in different industrial activities. The calculation program is meant to be used as a preliminary mapping of solvent emissions.