Introduction
Systems
Working instructions
Product data sheet
Colors
Paint calculator
Safety Data Sheets
 

Temacryl AR 50

A one-component, physically drying, semi-gloss, acrylic-based topcoat for e.g. bridges, cranes, conveyors, harbour equipment and tank exteriors.

The paint is solvent-borne
The coverage of the paint on rough surfaces
5,7
m2/l
The coverage of the paint on smooth surfaces
10
m2/l

High film-building properties

Temacryl AR 50 is a one-component acrylic based paint with hign film-building properties. It can be easily apply up to 175 µm wet film thickness without any sagging.

Can be applied at low temperatures

Temacryl AR 50 can be used even in - 5 ºC. The topcoat also withstands temperatures up to +80°C dry heat.



Temacryl AR 50 is used for




PRODUCT DATA SHEET
30.12.2005

Temacryl AR 50 - Acrylic topcoat

 
Temacryl AR50
DESCRIPTION A physically drying, one-component semi-gloss acrylic based topcoat.
PRODUCT FEATURES Recommended for surfaces exposed to marine or industrial climates and mild chemical stress.
Recommended uses Bridges, cranes, conveyors, harbour equipment and tank exteriors.

TECHNICAL DATA
Features High film build properties. Can be applied at low temperatures. Tolerates temperatures up to 80 ºC dry heat.
Colour Cards RAL, NCS, SSG, BS, MONICOLOR NOVA and SYMPHONY colour cards. TEMASPEED tinting.
Gloss groups Semi-gloss
Coverage

Recommended film thicknesses

Theoretical coverage

dry

wet

 

40 µm

100 µm

10.0 m2/l

70 µm

175 µm

5.7 m2/l


Practical coverage depends on the application method, painting conditions and the shape and roughness of the surface to be coated.
Thinner 1006 and 1053
Application method By airless spray or brush.
Drying times

DFT 50 µm

+ 10 ºC

+ 23 ºC

+ 35 ºC

Dust dry, after

1½ h

1 h

½ h

Touch dry, after

4 h

3 h

1 h

Recoatable, after

5 h

4 h

3 h


Drying and recoating times are related to the film thickness, temperature, the relative humidity of the air and ventilation.
Solids volume 40 ± 2 % volume (ISO 3233)
55 ± 2 % weight
Density 1.1 - 1.3 kg / l depending on colour
Product code 198-series

APPLICATION DETAILS
Application conditions All surfaces must be dry. The temperature of the ambient air, surface or paint should not fall below - 5 ºC during application and drying. Relative humidity should not exceed 85 %. The surface temperature of the steel should remain at least 3 ºC above the dew point.
Preparation Primed surfaces: Oil, grease, salt and dirt are removed from the surface by appropriate means. Repair any damage to the primer coat. Note the overcoating time of primer. (ISO 12944-4)
Priming TEMANYL MS PRIMER, TEMASIL 90, TEMAZINC 77, TEMAZINC 88 and TEMAZINC 99.
Finishing TEMACRYL AR 50.
Painting By airless spray or brush. Mix the paint thoroughly before use. Depending on the application method the paint can be thinned 0 - 15 %. Airless spray nozzle tip 0.013" - 0.019" and pressure 120 -180 bar. Spray angle shall be chosen according to the shape of the object.
Cleaning of tools Thinner 1006 or Thinner 1053.
EU VOC 2004/42/EC-limit value The Volatile Organic Compounds amount is 540 g/litre of paint.
VOC of the paint (thinned 15 % by volume) is 590 g/l.

HEALTH AND SAFETY LABELLING
according to Regulation (EC) No. 1272/2008
Containers are provided with safety labels, which should be observed. Further information about hazardous influences and protection are detailed in individual health and safety data sheets. A health and safety data sheet is available on request from Tikkurila Oy.
Safety data sheetTemacryl AR 50
Thinner safety data sheetTemacryl AR 50
 
-


Back