Temafloor 200 Primer

A two-component solvent-free epoxy lacquer for priming of new and old concrete floors.

The paint is suitable for interior floorsThe paint is solvent-borneTool: rollerTyöväline: teräslasta
The coverage of the paint on rough surfaces
4
m2/l
The coverage of the paint on smooth surfaces
10
m2/l

For fast priming

Temafloor 200 Primer gives good adhesion for Temafloor coatings and screeds and dries fast. Short overcoating time enables whole system application in one day.

Good primer for patching

Mixed with sand Temafloor 200 Primer is also suitable for patching of concrete floors.


Temafloor 200 Primer is mainly used for:




PRODUCT DATA SHEET
17.06.2013

Temafloor 200 Primer - Solvent-free epoxy varnish

 
Temafloor 200 Primer
DESCRIPTION A two-component solvent-free epoxy varnish.
PRODUCT FEATURES For priming of new and old concrete floors prior to laying Temafloor coatings and screeds. Thinned Temafloor 200 Primer penetrates well into the pores of the concrete sealing the surface and giving good adhesion for coatings and screeds. Mixed with sand also suitable for patching of concrete floors.
Recommended uses Concrete floors.

TECHNICAL DATA
Gloss groups Full-gloss
Coverage

Coverage on concrete floors is on the average:

1st primer coat                     4 - 8 m2/l

2nd primer coat                  6 - 10 m2/l

 

Practical coverage depends on the porosity and evenness of the substrate and on the application method.
Thinner 1029 and 1031
Mixing ratio Base 2 parts by volume 008 4400
Hardener 1 part by volume 008 4406
Application method Roller, steel or rubber trowel.
Pot-life (+23°C) About 15 minutes after mixing, on substrate.
Drying time at 23°C and 50% relative air humidity

Dust dry after 3 hours

Touch dry after 5 hours

Recoatable after 6 - 12 hours

Light trucking after 16 hours

Fully cured after 7 days

 

The drying times are for Temafloor 200 Primer thinned 30 % with Thinner 006 1029.
Solids volume Approx. 100 volume %
Density 1.1 kg / litre (mixture)
Product code 008 4400

APPLICATION DETAILS
Application conditions The relative humidity of the concrete should not exceed 97%. The temperature of the ambient air, surface or coating should not fall below +15ºC during application or drying. Relative humidity of air should not exceed 80%.
Preparation New concrete
Remove laitance by power grinding, vacuum grit blasting or hydrochloric acid etching. Choose the method best suited for the premises. After grinding remove dust carefully with a vacuum cleaner. Hydrochloric acid etching is carried out with diluted hydrochloric acid (1 part concentrated hydrochloric acid, 4 parts water). Rinse with plenty of water. Dry the floor.

Old concrete
Remove all grease, oil, chemicals and other impurities by MAALIPESU detergent. Remove old peeling paint layer by grinding or vacuum grit blasting. Clean out pot-holes removing all loose friable material. Open cracks with e.g. an abrasive tool. Remove loose material and dust.

Cementitious levelling screed
Check compatibility with the levelling screed manufacturer.
Priming Prime using 30-50% thinned Temafloor 200 Primer epoxy varnish. Pour the varnish onto the floor and apply as much as is needed to impregnate the concrete surface. If necessary, repeat priming to get a non-porous surface. Subsequent treatment can be carried out after 2 hours using "wet-on-wet" technique.
Patching Patch pot-holes and cracks with a mixture of unthinned Temafloor 200 Primer epoxy varnish and dry, clean sand. Mixing ratio e.g. 1 part by volume of varnish mixture and 1-2 parts by volume of sand of grain size 0.1-0.6 mm. If the topcoat will be applied as a thin layer, grind the patched areas before overcoating.
Coating Overcoating may be carried out 6-12 hrs after priming. If the primed surface is not overcoated within 24 hrs, it should be abraded. A porous primer coat will result in holes and air bubbles in the finished coating.
Mixing of components Mix the correct proportions of base and hardener thoroughly (approx. 2 minutes) by using an industrial hand drill with a paddle. The amount of mixture depends on the area to be coated and on the pot life of the mixture. Insufficient mixing or incorrect mixing ratio will result in uneven drying of the surface, weaken the properties of the coating and risk the success of the application.
Cleaning of tools Thinner 006 1029 (or Thinner 006 1031).
EU VOC 2004/42/EC-limit value VOC 2004/42/EC (cat A/j) 500 g/l (2010)
Temafloor 200 Primer: max. VOC < 500 g/l

HEALTH AND SAFETY LABELLING
according to Regulation (EC) No. 1272/2008
Containers are provided with safety labels, which should be observed. Further information about hazardous influences and protection are detailed in individual health and safety data sheets. A health and safety data sheet is available on request from Tikkurila Oyj.
Safety data sheetTemafloor 200 Primer
Thinner safety data sheetTemafloor 200 Primer
Hardener safety data sheetTemafloor 200 Primer

DECLARATION OF PERFORMANCE Declaration of Performance EN13813 Declaration of Performance EN1504-2
 
-


CE
The European harmonized productstandard EN 13813 defines the requirements for Screed materials and floor screeds, including synthetic resin screeds.
This product is tested and CE-labelled in accordance with the tables ZA.1.5 and ZA.3.3 in the appendix ZA.3.
CE logo
Tikkurila Oyj
Kuninkaalantie 1
FI-01300 VANTAA
11
TIK-8400-5008b
0809-CPD-0773
EN 13813 SR-B2,0
Primer
Abrasion resistance
NPD
Chemical resistance
NPD
Release of corrosive substances
SR
Impact resistance
NPD
Sound insulation
NPD
Sound absorption
NPD
Thermal resistance
NPD
Reaction to fire
Efl 1)
Water permeability
NPD
1) In accordance with Comission decision 2010/85/EC


CE
The European harmonized productstandard EN 1504-2 defines the requirements for surface protection systems for concrete.
This product is tested and CE-labelled in accordance with the tables 1d and 1f in the appendix ZA as part of coating systems.
CE logo
0809
Tikkurila Oyj
Kuninkaalantie 1
FI-01300 VANTAA
13
TIK-8400-5008a
0809-CPD-0773
EN 1504-2:2004
Product for protection and repair of concrete structures – Coating
Abrasion resistance
according to surface product
Resistance to severe chemical attack
according to surface product
Permeability to CO2
According to the top coat
Water absorption
According to the top coat
Impact resistance
According to the top coat