A two-component solvent-free epoxy lacquer for new and old concrete floor, and also as a binder for Temafloor 4000 troweling screed.

The paint is suitable for interior floorsThe paint is solvent-borneTool: rollerTyöväline: teräslasta
The coverage of the paint on rough surfaces
5
m2/l
The coverage of the paint on smooth surfaces
10
m2/l

Multi-purpose epoxy lacquer

Temafloor 400 is excellent product for dust binding and priming of new and old concrete floors, especially where solventless and odourless products are needed. The lacquer can be used for patching when filled with sand.

Suitable for priming, screeding and topcoating

This lacquer is a main component of Temafloor 4000 grinding screed.  Temafloor 400 also can be apply on the top of Temafloor coatings and screeds. It can be used with mosaic flakes as a top lacquer to increase anti-slip properties.


Temafloor 400 is widely used for




PRODUCT DATA SHEET
01.12.2014
(Previous date 16.06.2013)

Temafloor 400 - Solvent-free epoxy varnish

 
Temafloor 400
DESCRIPTION A two-component solvent-free epoxy varnish.
PRODUCT FEATURES Used as a binder for Temafloor 4000 grinding screed and epoxy concrete. Used also as a topcoat on top of Temafloor coatings and screeds.
Recommended uses Suitable for dust binding and priming of new and old concrete floors under Temafloor coatings. Filled with sand also suitable for patching of concrete floors.

TECHNICAL DATA
Features Fire classification according to standard EN 13501 is BFL-s1.
Gloss groups Full-gloss
Coverage

Coverage on concrete floors is on the average:

Primer                                 5 - 8 m2/l

Topcoat                             6 - 10 m2/l

 

Practical coverage depends on the porosity and evenness of the substrate and on the application method.
Thinner 1029
Mixing ratio Base 3 parts by volume 008 4403
Hardener 1 part by volume 008 4408
Application method Rubber trowel and roller.
Pot-life (+23°C) Approx. 30 minutes after mixing, on substrate.
Drying time at 23°C and 50% relative air humidity

Dust dry after 6 hours

Recoatable after 16 - 24 hours

Fully cured 7 days
Solids volume approx. 100 volume %
Density 1.1 kg / litre (mixture)
Product code Base paint 008 4403, hardener 008 4408.

APPLICATION DETAILS
Application conditions The relative humidity of the concrete should not exceed 97%. The temperature of the ambient air, surface or coating should not fall below +15ºC during application or drying. Relative humidity of air should not exceed 80%.

Note! There is a natural tendency of epoxy coatings to chalk and discolor on exterior exposure.
Preparation New concrete
Remove laitance by power grinding, vacuum grit blasting or hydrochloric acid etching. Choose the method best suited for the premises. After grinding remove dust carefully with a vacuum cleaner. Hydrochloric acid etching is carried out with diluted hydrochloric acid (1 part concentrated hydrochloric acid, 4 parts water). Rinse with plenty of water. Dry the floor.

Old concrete
Remove all grease, oil, chemicals and other impurities by MAALIPESU detergent. Remove old peeling paint layer by grinding or vacuum grit blasting. Choose the method best suited for the premises. Clean out pot-holes removing all loose friable material. Open cracks with e.g. an abrasive tool. Remove loose material and dust.

Cementitious levelling screed
Check compatibility with the levelling screed manufacturer.
Priming Prime using about 30% thinned Temafloor 400 epoxy varnish. Pour the varnish onto the floor and apply as much as is needed to impregnate the concrete surface. If necessary, repeat the priming to get a non-porous surface. Subsequent treatment can be carried out after 2 hours using "wet-on-wet" technique.
Patching Patch pot-holes and cracks with a mixture of unthinned Temafloor 400 epoxy varnish and dry, clean sand. Mixing ratio e.g. 1 part by volume of epoxy mixture and 1-2 parts by volume of sand of grain size 0.5-1.2 mm.
Overcoating Overcoating should be done within 16–24 hrs after priming. If the primed surface is not overcoated within 24 hrs, it should be abraded. Use 20–30% thinned Temafloor 400 varnish as a topcoat. Pour the varnish mixture onto the floor, spread with a rubber or a steel trowel and level with a roller. Suitable roller is e.g. felt or nylon roller which “distributes” the varnish well. Length of the fluff is approx. 5–14 mm.
Mixing of components Mix the correct proportions of base and hardener thoroughly (approx. 2 minutes) by using a low speed hand drill with a paddle. The amount of mixture depends on the area to be coated and on the pot life of the mixture. Insufficient mixing or incorrect mixing ratio will result in uneven drying of the surface, weaken the properties of the coating and risk the success of the application.
Cleaning of tools Thinner 006 1029.
EU VOC 2004/42/EC-limit value VOC 2004/42/EC (cat A/j) 500 g/l (2010)
Temafloor 400: max. VOC < 500 g/l

HEALTH AND SAFETY LABELLING
according to Regulation (EC) No. 1272/2008
Containers are provided with safety labels, which should be observed. Further information about hazardous influences and protection are detailed in individual health and safety data sheets. A health and safety data sheet is available on request from Tikkurila Oyj.
Safety data sheetTemafloor 400
Thinner safety data sheetTemafloor 400
Hardener safety data sheetTemafloor 400

DECLARATION OF PERFORMANCE Declaration of Performance EN13813 Declaration of Performance EN1504-2
 
-


CE
The European harmonized productstandard EN 13813:2002 defines the requirements for Screed materials and floor screeds, including synthetic resin screeds.

This product is tested and CE-labelled in accordance with the tables ZA.1.5 and ZA.3.3 in the appendix ZA.3.
CE logo
Abrasion resistanceRWA 10 as Temafloor 4000Chemical resistanceCR 1, 2, 5, 6b, 7…8, 10…12, 14 (Class 2)Release of dangerous substancesNPDRelease of corrosive substancesSRImpact resistanceIR4Sound insulationNPDSound absorptionNPDThermal resistanceNPDReaction to fireBfl-s1 Adhesion strength by pull off testB 2.0
Tikkurila Oyj
Kuninkaalantie 1
FI-01300 VANTAA
11
TIK-8400-5005b
EN 13813 SR-RWA10-B2,0-IR 4
Synthetic resin screed


CE
The European harmonized productstandard EN 1504-2 defines the requirements for surface protection systems for concrete.
This product is tested and CE-labelled in accordance with the tables 1d, 1f and 1g in the
appendix ZA.
CE logo
0809
Abrasion resistance< 3000 mgResistance to severe chemical attackClass IIRelease of dangerous substancesNPDPermeability to CO2CO2sD > 50 mImpact resistanceClass I: ≥ 4 NmPermeability to water vapourClass II, 5 m < sD < 50 m
Tikkurila Oyj
Kuninkaalantie 1
FI-01300 VANTAA
13
TIK-8400-5005a
0809-CPD-0773
EN 1504-2:2004
Product for protection and repair of concrete structures – Coating