PRODUCT DATA SHEET
02.04.2014

Temafloor AC610 Clear - Solvent-free acrylic top lacquer

 
Temafloor AC610 Clear
DESCRIPTION A two-component, solvent-free acrylic top lacquer.
PRODUCT FEATURES

Suitable for topcoating of Temafloor AC509 and Temafloor AC501 acrylic screeds. Especially for hard mechanical abrasion in dry interior premises.

Recommended uses Suitable for dry indoor premises, such as corridors, retail stores, changing rooms etc.

TECHNICAL DATA
Features Excellent resistance to abrasion and scratches.
Good resistance to chemicals.
Colour Range Sunlight will affect on the shade and the gloss of the varnish in the long run.
Gloss groups Gloss
Coverage

Temperature (oC)*

The amount of hardener (percentage of weight of the binder)

Pot life (min)

Drying time (min)

+10

1.5

ab. 25

ab. 45

+20

1.5

ab. 15

ab. 35

+25

1.0

ab. 12

 ab. 25

+30

1.0

ab. 8

 ab. 15










* Temperature of the binder, air and the floor.

Coverage is on the average:

Topcoat                          1.5–3.3 m2/l

Practical coverage depends on the porosity and evenness of the surface and on the application method.
Can sizes 200 l drum, content 190 kg
Application method Apply with a rubber spatula and level with roller.
Solids volume approx. 100 vol-%.
Density 0.99 kg /l (ready made mixture)
Product code 001 6093

APPLICATION DETAILS
Application conditions The relative humidity of the concrete should not exceed 97%. The temperature of the ambient air, surface or coating should not fall below +5ºC during either application or drying. Relative humidity of air should not exceed 80%.
Preparation New concrete
Remove laitance by power grinding, vacuum grit blasting or hydrochloric acid etching. Choose the method best suited for the premises. After grinding remove dust carefully with a vacuum cleaner. Hydrochloric acid etching is carried out with diluted hydrochloric acid (1 part concentrated hydrochloric acid, 4 parts water). Rinse with plenty of water. Dry the floor.

Old concrete
Remove all grease, oil, chemicals and other impurities by MAALIPESU detergent. Remove old peeling paint layer by grinding, milling or vacuum grit blasting. Choose the method best suited for the premises. Clean out pot-holes removing all loose friable material. Open cracks with e.g. an abrasive tool. Remove loose material and dust.
Diluting Do not thin.
Lacquering Topcoating can be carried out after the coating or screed has cured. Pour the mixture onto the floor, spread with a rubber trowel and level with a roller.
Observe a right amount of hardener. Using excessive amounts of hardener can cause yellowing and weaken the properties of the topcoat. Film thickness of Temafloor AC610 Clear should be 0.3–0.7 mm. Larger or too thick film thickness may also cause yellowing and delamination of the topcoat.
Mixing of components Mix the correct proportions of base and hardener powder thoroughly (approx. 2 minutes) by using a hand drill with a paddle, concrete mixer or power mixer. The amount of mixture depends on the area to be coated and on the pot life of the mixture. Insufficient mixing or incorrect mixing ratio will result in uneven drying of the surface, weaken the properties of the varnish and risk the success of the application.
Cleaning of tools Cleaning of equipment with Thinner 006 1400 or Temafloor AC Clean.
EU VOC 2004/42/EC-limit value VOC 2004/42/EC (cat A/j), 500 g/l (2010)
Temafloor AC609 Clear: max. VOC < 500 g/l


HEALTH AND SAFETY LABELLING
according to Regulation (EC) No. 1272/2008
Containers are provided with safety labels, which should be observed. Further information about hazardous influences and protection are detailed in individual health and safety data sheets. A health and safety data sheet is available on request from Tikkurila Oyj. For professional use only.
Safety data sheetTEMAFLOOR AC610 CLEAR en
 
-


CE
The European harmonized productstandard EN 1504-2:2004 defines the requirements for surface protection systems for concrete.

This product is tested and CE-labelled in accordance with the tables 1d, 1f and 1g in the appendix ZA.

CE logo
0809
Abrasion resistanceResistance to severe chemical attack< 3000 mgClass IAdhesion by cross-cut testCO2sD > 50 mAdhesion by cross-cut testClass I: ≥ 4 NmPermeability to water vapourPermeability to water vapour:Capillary absorption and permeability to waterw < 0,1 kg/m² ∙ h0,5Adhesion strength by pull off test≥ 2,0 N/mm²Reaction to fireEfl
Tikkurila Oyj
Kuninkaalantie 1
FI-01300 VANTAA
14
TIK-1600-5008
0809-CPD-0773
EN 1504-2:2004
Product for protection and repair of concrete structures – Coating
1) Tested as part of a system together with Temafloor AC 102 Primer and Temafloor AC 509.


Back