PRODUCT DATA SHEET
13.01.2014
(Previous date 17.06.2013)

Temafloor 150 - Epoxy paint

 
Temafloor 150
DESCRIPTION A two-component solvent-free epoxy paint.
PRODUCT FEATURES A solvent-free epoxy paint for floors indoors and outdoors. For new and old concrete floors and for surfaces previously treated with epoxy paints. Recommended for floors exposed to moderate chemical and mechanical stress in industrial and storage facilities, repair shops etc.
Recommended uses Suitable for coating of asphalt floors, floors of garages, staircases, balconies, washing facilities, cellars etc.

TECHNICAL DATA
Features Withstands +70ºC dry heat and +60ºC in immersion. Temafloor Flex hardener makes the paint surface flexible and thus more resistant to cracking of concrete. Fire classification according to standard EN 13501-1 is BFL-s1.
Colour Cards RAL, NCS, SSG, BS, MONICOLOR NOVA and SYMPHONY colour cards. TEMASPEED tinting.
Gloss groups Full-gloss
Coverage

Coverage on concrete floors is on the average:

Primer                                 4 - 6 m2/l

Topcoat                               6 - 8 m2/l

 

Practical coverage depends on the porosity and evenness of the substrate and on the application method.
Thinner 1029
Mixing ratio Base 4 parts by volume 102-series
Hardener 1 part by volume 008 4151

or

Base 2 parts by volume 102-series
Flex hardener 1 part by volume 930 5002
Application method Pour the mixture onto the floor, apply with a steel or rubber trowel and level with a roller.
Pot-life (+23°C) Approx. 20 minutes after mixing, on substrate.
Drying time at 23°C and 50% relative air humidity

Dust dry after 4 hours

Recoatable after 8 hours - 2 days

Light trucking after 24 hours

Fully cured after 7 days

 

At lower temperature the curing process will last longer.

With Temafloor Flex hardener the curing times are a little longer than with standard hardener.

Solids volume approx. 100 volume %
Density 1.7 kg / litre (mixture)
Product code Base paint 102-series. Hardener 008 4151 or Flex hardener 930 5002.

APPLICATION DETAILS
Application conditions The relative humidity of the concrete should not exceed 97%. The temperature of the ambient air, surface or coating should not fall below +15ºC during application or drying. Relative humidity of air should not exceed 80%.
Note! There is a natural tendency of epoxy coatings to chalk and discolor on exterior exposure.
Preparation New concrete
Remove laitance by power grinding or hydrochloric acid etching. Choose the method best suited for the premises. After grinding remove dust carefully with a vacuum cleaner. Hydrochloric acid etching is carried out with diluted hydrochloric acid (1 part concentrated hydrochloric acid, 4 parts water). Rinse with plenty of water. Dry the floor.

Old concrete
Remove all grease, oil, chemicals and other impurities by MAALIPESU detergent. Remove old peeling paint layer by grinding. Choose the method best suited for the premises. Clean out pot-holes removing all loose friable material. Open cracks with e.g. an abrasive tool. Remove loose material and dust.

Cementitious levelling screed
Check compatibility with the levelling screed manufacturer.
Priming Prime using 10 - 30% thinned Temafloor 150 epoxy paint. Pour the mixture immediately onto the floor, apply with a steel or rubber trowel and level with a roller.
Patching Patch pot-holes and cracks with Colofill putty or a mixture of unthinned Temafloor 150 epoxy paint or Temafloor 200 Primer or 210 epoxy varnish and dry, clean sand. Mixing ratio
e.g. 1 part by volume of epoxy paint or varnish mixture and 1 - 2 parts by volume of sand of grain size 0.1 - 0.6 mm. Grind the patched areas before overcoating.
Finishing Overcoating may be carried out not earlier than 8 hrs after priming. If the primed surface is not overcoated within 48 hrs, it should be abraded. The paint should be thinned 5 - 20%. Pour the mixture onto the floor, apply with a steel or rubber trowel and level with a roller.
Mixing of components Mix the correct proportions of base and hardener thoroughly (approx. 2 minutes) by using an industrial hand drill with a paddle. The amount of mixture depends on the area to be coated and on the pot life of the mixture. Insufficient mixing or incorrect mixing ratio will result in uneven drying of the surface, weaken the properties of the coating and risk the success of the application.
Cleaning of tools Thinner 006 1029.
EU VOC 2004/42/EC-limit value VOC 2004/42/EC (cat A/j) 500 g/l (2010)
Temafloor 150: max. VOC < 500 g/l

HEALTH AND SAFETY LABELLING
according to Regulation (EC) No. 1272/2008
Containers are provided with safety labels, which should be observed. Further information about hazardous influences and protection are detailed in individual health and safety data sheets. A health and safety data sheet is available on request from Tikkurila Oyj.
Safety data sheetTemafloor 150
Thinner safety data sheetTemafloor 150
Hardener safety data sheetTemafloor 150

DECLARATION OF PERFORMANCE Declaration of Performance EN1504-2
 
-


CE
The European harmonized productstandard EN 1504-2 defines the requirements for surface protection systems for concrete.
This product is tested and CE-labelled in accordance with the tables 1d, 1f and 1g in the appendix ZA.
CE logo
0809
Tikkurila Oyj
Kuninkaalantie 1
FI-01300 VANTAA
13
TIK-0102-5001
0809-CPD-0773
EN 1504-2:2004
Product for protection and repair of concrete structures – Coating
Abrasion resistance
< 3000 mg
Resistance to severe chemical attack
Class II
Release of dangerous substances
NPD
Permeability to CO2
CO2sD > 50 m
Impact resistance
Class I: ≥ 4 Nm
Capillary absorption and permeability to water
w < 0,1 kg/m² ∙ h0,5


Back