PRODUCT DATA SHEET
04.10.2013
(Previous date 18.02.2013)

Temaline EPL 100 - Epoxy-phenolic paint

 
Temaline EPL 100
DESCRIPTION A two-component epoxy-phenolic paint.
PRODUCT FEATURES

Resistant to dilute solutions of non-oxidizing acids, alkali and salts in immersion

Resistance to fuels and chemicals as listed in the separate chemical resistance table.

Suitable for immersion of hot water between +65ºC–90ºC.

Withstands dry heat up to +150ºC, but discolouration possible.
Recommended uses -

TECHNICAL DATA
Colour Range White, beige (RAL1015) and light grey (RAL 7032 and 7044).
Gloss groups Semi-gloss
Coverage

Recommended film thicknesses

Theoretical coverage

dry

wet

 

100µm

130µm

7.7 m2/l

150µm

200µm

5.0 m2/l


Practical coverage depends on the application method, painting conditions and the shape and roughness of the surface to be coated.
Thinner 1031
Mixing ratio Base 5 parts by volume 25V 7005
Hardener 1 part by volume 008 5612

Pot-life (+23°C) 1 hour.
Drying times

DFT 125µm

+10ºC

+23ºC

+35ºC

Dust dry, after

12h

4h

2h

Touch dry, after

24h

7h

5h

Recoatable, after

30h

10h

8h

Recoatable, max. without sanding

3d

48h

24h


Drying and recoating times are related to the film thickness, temperature, the relative humidity of the air and ventilation.
Solids volume 72 ± 2 % (ISO 3233).
83 ± 2 %
Density 1.45 kg / litre (mixed).
Product code 25V 7005

APPLICATION DETAILS
Application conditions All surfaces must be dry. The temperature of the ambient air, surface or paint should not fall below +10ºC during application or drying. Relative humidity should not exceed 80%. The surface temperature of the steel should remain at least 3ºC above the dew point.
Preparation Oil, grease, salts and dirt are removed by appropriate means. (ISO 12944-4)

Steel surfaces: Blast clean to grade Sa2½ (ISO 8501-1).
Finishing Temaline EPL 100.
Priming Temaline EPL 100.
Painting By spray or brush. Depending on the application method the paint can be thinned 0-5%. Airless spray nozzle tip 0.015"-0.019". Spray angle shall be chosen according to the shape of the object.
Mixing of components First stir base and hardener separately. The correct proportions of base and hardener must be mixed thoroughly before use. Use mechanical mixer for mixing.
Cleaning of tools Thinner 1031.
EU VOC 2004/42/EC-limit value The Volatile Organic Compounds amount is 240 g/litre of paint mixture.
VOC content of the paint mixture thinned 5% by volume is 270 g/l.

HEALTH AND SAFETY LABELLING
according to Regulation (EC) No. 1272/2008
Containers are provided with safety labels, which should be observed. Further information about hazardous influences and protection are detailed in individual health and safety data sheets. A health and safety data sheet is available on request from Tikkurila Oyj. For industrial and professional use only.
Safety data sheetTemaline EPL 100
Thinner safety data sheetTemaline EPL 100
Hardener safety data sheetTemaline EPL 100
 
-