Introduction
Systems
Working instructions
Product data sheet
Colors
Paint calculator
Safety Data Sheets
 
UV-curing, tintable water-borne urethane polyester paint for interior wooden surfaces.

The paint is water-borneTool: spray
The coverage of the paint on rough surfaces
8
m2/l
The coverage of the paint on smooth surfaces
10
m2/l

Thousands of durable colors

Due to the tintability Luminol 25 paints are now the favourite products for e.g. kitchen cabinet producers.  They allow you to achieve a broad variety of colors with excellent durability of the surface.

Excellent stacking properties

Luminol paints have been developed for fast production lines. They have excellent stacking properties straight after the oven.

Good abrasion resistance

WB UV-curing products have better chemical, scratch and abrasion resistance than conventional WB products. They are a brilliant choice for interior doors, moldings, the doors of kitchen fittings and
other interior surfaces.


Find a brochure here:


Luminol - Colorful durable solutions with UV-curing base paints
Luminol_brochure_small

Luminol is a tintable UV-curing paint that allows you to achieve a broad variety of colors with better chemical, scratch and abrasion resistance than conventional water-borne products.

Luminol

Luminol 25 is mostly used for:



PRODUCT DATA SHEET
24.04.2017

Luminol 25

 
Tikkurila Industry 9L
DESCRIPTION UV-curing, tintable water-borne paint.
PRODUCT FEATURES Wooden interiro surfaces.
Recommended uses Recommended for interior doors, moldings, doors of kitchen fittings and other wooden surfaces.

TECHNICAL DATA
Features • Thousands of durable colors
• Excellent stacking properties
• Good abrasion resistance
• Can be reused because the paint does not dry during painting process.
Colour Cards The product belongs to Avatint tinting system.
Gloss groups Semi-matt
Coverage

Recommended spreading amounts (unthinned)

Theoretical coverage

dry

wet

 

30–40 µm

100–140 g/m²

8–10 m2/l


Practical coverage depends on the application method, painting conditions and the shape and roughness of the surface to be coated.
Thinner Water
Application method Airless spraying, air-assisted airless spraying and conventional spraying.
Drying times

Dry to stack immediately after UV curing.

Water should be allowed to flash off before UV curing.

 

Flash-off time depends on the temperature and the amount and the speed of the air.

Required UV-energy: 500 mJ/cm2 + 500 mJ/cm2. For proper curing use both Gallium and Mercury lamps in UV-curing.
Solids volume A-base 34% by volume
C-base 31% by volume

A-base 47% by weight
C-base 38% by weight

Density A-base 1.8 kg/litre, C-base 1.1 kg/ltre
Product code 157- series

APPLICATION DETAILS
Application conditions The surface to be treated has to be clean and dry. During application and drying the temperature of the air, the surface to be treated and the lacquer has to be over +18ºC and the relative humidity of the air below 70%.
Preparation Remove dust, loose particles and other impurities from the surface. Wood surfaces should be sanded with sandpaper P150–240. Primed surfaces should be sanded with sandpaper P240–600. All sanding dust must be removed.
Priming Recommended primers/topcoats: Uvicol Primer, Uvinol Sealer HB, Akvi Primer Pro, Akvi Primer DS and Dicco Surf Delfi Beige.
Painting For airless spraying, the product is thinned approximately 0–5% to the viscosity
50–120 s (DIN4). Recommended nozzle tip is 0.011"–0.015" and pressure 80–160 bar. Choose the spray angle according to the shape of the object.

For air–assisted airless spraying, the product is thinned approximately 0–5% to the viscosity 50–120 s (DIN4). Recommended nozzle tip is 0.011"–0.015" and pressure
40–140 bar. Atomising air pressure should be about 1–3 bar. Choose the spray angle according to the shape of the object.

For conventional spraying, the product is thinned approximately 0–10 % to the viscosity 50–70 s (DIN4). Recommended nozzle tip is 1.4–1.8 mm and pressure 2–3 bar.
Cleaning of tools Water.
EU VOC 2004/42/EC-limit value The Volatile Organic Compounds amount is 7 g/litre of paint.

HEALTH AND SAFETY LABELLING
according to Regulation (EC) No. 1272/2008
Further information about hazardous influences and protection are detailed in individual health and safety data sheets. A health and safety data sheet is available on request from Tikkurila Oyj. For industrial and professional use only.
Safety data sheetLuminol 25
 
-


Back