PRODUCT DATA SHEET
02.01.2018
(Previous date 21.10.2016)

Temabond ST 200 - High-solids epoxy paint

 
Temabond ST200
DESCRIPTION A two-component high-solids, aluminium pigmented modified epoxy maintenance paint for demanding surfaces.
PRODUCT FEATURES

An ideal solution for maintenance painting due to very good adhesion even to hand prepared steel.

Resists immersion in water and can therefore be used e.g. in steel structures in water and soil immersion.

Can also be applied on old alkyd paint surfaces.

Can be used as a single-coat paint.


Winter grade version Temabond WG 200 can be cured at lower temperatures.
Recommended uses Used in systems for repainting and touch-up painting of steel surfaces difficult to clean such as bridges, cisterns and different types of steelwork and equipment in wood-processing and chemical industry. Recommended for repairing of damages caused by transport or installation.

TECHNICAL DATA
Features Due to the aluminium pigmentation forms a very tight coat with good chemical and abrasion resistance.
High film-build properties, also by brush.
As a high-solids product Temabond ST 200 has lower VOC emissions than traditional epoxy paints.
Colour Range Aluminium (Temaspeed tinting for reddish aluminium). The colour will change in outdoor use.
Gloss groups Semi-gloss
Coverage

Recommended film thicknesses

Theoretical coverage

dry

wet

 

100 µm

125 µm

8.0 m2/l

200 µm

250 µm

4.0 m2/l


Practical coverage depends on the application method, painting conditions and the shape and roughness of the surface to be coated.
Thinner 1031
Mixing ratio Base 1 part by volume Temabond ST 200
Hardener 1 part by volume 008 7501
Application method By airless spray or by brush.
Pot-life (+23°C) 1½ hours
Drying times

DFT 150 µm

+ 10 ºC

+ 23 ºC

+ 35 ºC

Dust dry, after

6 h

3 h

1½ h

Touch dry, after

14 h

5½ h

3½ h

Recoatable, after

30 h

8 h

5 h

Recoatable without sanding, after max.

2 months

1 month

7 d


Drying and recoating times are related to the film thickness, temperature, the relative humidity of the air and ventilation.
Solids volume 80 ± 2 volume % (ISO 3233)
87 ± 2 weight %
Density 1.4 kg / l (mixed)
Product code Base paint 008 7298, Hardener 008 7501

APPLICATION DETAILS
Application conditions All surfaces must be dry. The temperature of the ambient air, surface or paint should not fall below +10 ºC during application and drying. Relative humidity should not exceed 80 %. The surface temperature of the steel should remain at least 3 ºC above the dew point.
Preparation Oil, grease, salts and dirt are removed by appropriate means. (ISO 12944-4)

Steel surfaces: Remove rust by tool cleaning to minimum St2 or blast clean to Sa2 or Sa2½. Blast clean to grade Sa2½ for immersion. (ISO 8501-1)

Earlier painted surfaces: Roughen old paint surfaces using e.g. abrasive wheel, sand paper or blast cleaning.
Priming Temabond ST 200, Temazinc 77 and Temazinc 99.
Finishing Temacoat GPL, Temacoat GPL-S MIO, Temacoat GPL-S Primer, Temacoat GS 50, Temacoat RM 40, Temabond ST 300, Temadur, Temathane and Temacryl EA.
Painting For airless spraying, the product is thinned approximately 0–10%. Recommended nozzle tip is 0.013"–0.019" and pressure 140–180 bar. Spray angle shall be chosen according to the shape of the object.

For brush application the product should be thinned according to the circumstancies.
Mixing of components First stir base and hardener separately. The correct proportions of base and hardener must be mixed thoroughly before use. Use power mixer for mixing. Insufficient mixing or incorrect mixing ratio will result in uneven drying of the surface and weaken the properties of the coating.
Cleaning of tools Thinner 006 1031.
EU VOC 2004/42/EC-limit value The Volatile Organic Compounds amount is 200 g/litre of paint mixture.
VOC content of paint mixture (thinned 10 % by volume) is 260 g/l.

For industrial and professional use only.


HEALTH AND SAFETY LABELLING
according to Regulation (EC) No. 1272/2008
Containers are provided with safety labels, which should be observed. Further information about hazardous influences and protection are detailed in individual health and safety data sheets. A health and safety data sheet is available on request from Tikkurila Oyj.
Safety data sheetTemabond ST 200
Thinner safety data sheetTemabond ST 200
Hardener safety data sheetTemabond ST 200
 
-


Back