PRODUCT DATA SHEET
25.10.2017

GrafoTherm Line - Functional anti-condensation coating

 
GrafoTherm Line
DESCRIPTION A one-component water-borne anti-condensation coating for line application.
PRODUCT FEATURES
Recommended uses Recommended to be used for steel roofing sheets for interior and sheltered premises.

TECHNICAL DATA
Features Excellent moisture absorbing and evaporation properties.
Prevents from condensation and dripping water.
Forms very elastic and porous coating layer.

Complies with the requirements of EN13501-1, class A2-s1d0.

Colour Range White and grey.
Gloss groups Matt
Coverage

Recommended film thickness

Theoretical coverage

dry

wet

 

250–500 g/m2

600–1000 g/m2

1.8–0.9 m2/l

Recommended coverage depends on the ambient conditions like moisture and type of building etc.
See separate Grafotherm Treatment Programme.
Practical coverage depends on the application method, painting conditions and the shape and roughness of the surface to be coated.
Thinner Water
Application method Conventional spraying or plaster spray gun.
Drying times

Through dry

+80ºC

+150ºC

WFT 600 g/m2

10–15 min

4–5 min

WFT 1200 g/m2

30 min

15 min

Drying and recoating times are related to the film thickness, temperature, the relative humidity of the air and ventilation.


Water absorption approx. 330g/m2 of water, 600 g/m2 WFT (250g/m2 DFT), (NF P15-203-11997)
approx. 520 g/m2 of water, 1200 g/m2 WFT (500g/m2 DFT), (NF P15-203-11997)
Solids volume 41%
Density 1.05 kg/l
Product code 006 5123, 006 5124

APPLICATION DETAILS
Application conditions All surfaces must be dry. The temperature of the ambient air and surface should not fall below +10ºC during application and drying. Relative humidity should not exceed 80%. The surface temperature of the surface to be coated should remain at least 3ºC above the dew point.

The temperature of paint itself should be above +15°C for proper application.
Good ventilation is required in confined areas during application and drying.

Preparation Oil, grease, salts and dirt are removed by appropriate means. (ISO 12944-4)
Zinc and aluzinc surfaces: Remove possible grease, salt and dirt from the surface.

Primed surfaces: Industrial coil primer on the backside of the steel roofing sheets does not require any special preparation. Grease, salt and dirt are removed from the surface by appropriate means. Repair any damage to the primer coat with Temaprime EE or Rostex Super. Note the overcoating time of primer.
Priming Industrial coil sheet backside primer. Can be applied directly on galvanized thin steel (see Surface preparation).
Application Conventional spraying or plaster spray gun. Mix the paint thoroughly before use.
The paint can be thinned 0–5% by volume. Spray nozzle tip 6mm and nozzle pressure 2 bar. Air supply >1000 l/min (conventional spraying) and >250 l/min (plaster spray gun).
Finishing Do not overcoat with any other type of coating as it causes loss of absorbing properties.
Cleaning of tools Water.
EU VOC 2004/42/EC-limit value The Volatile Organic Compounds amount is < 3 g/litre of paint mixture.

HEALTH AND SAFETY LABELLING
according to Regulation (EC) No. 1272/2008
-
Safety data sheetGRAFOTHERM LINE EN
 
ENVIRONMENTAL and WASTE DISPOSAL Containers are provided with safety labels, which should be observed. Further information about hazardous influences and protection are detailed in individual health and safety data sheets. A health and safety data sheet is available on request from Tikkurila Oyj. Only for industrial use.
-